ConfigHub does not allow to edit the connector (the 'connect via') of an existing data source. The reason is that 2 connectors can run on different servers and if deletion of a data source in connector A or adding a data source in connector B fails, we could end up with a data source being deleted completely or being added twice. To avoid this potential risk, if a data source needs to be moved from connector A to connector B this needs to be manually executed via the connector API.

Prerequisites

  • The APIs of both connectors are reachable (can be called successfully).

  • The user performing the move knows the password of the user account configured on the data source which needs to be moved.

  • You'll need a TrendMiner user account with the admin role to run a global monitor health check.

The following steps can be executed on the respective connector API interfaces to move a data source from connector A to connector B:

  • Get the details of the data source you want to move away from connector A. This article shows the API call which can be used to get the details.

  • Copy the details of the data source to a text file. Example of the expected output:

    {
        "DbId": 21,
        "Name": "PI2018",
        "Prefix": "CS",
        "TagFilter": "",
        "Provider": "PIOLEDB",
        "DataSource": "cs-pi2018.trendminer.net",
        "UserId": "pi2018user",
        "Password": "********",
        "Version": "other",
        "OnlySupportsRawValues": false,
        "Properties": [
            {
                "key": "TAGFILTER",
                "value": ""
            }
        ]
    },
  • Delete the data source from connector A doing a DELETE /database/{id} call.

  • Edit the following in the data source details of the text file:

    • Remove the field “DbId” and its value

    • Replace the password value ************* with the actual password (between quotes)

    • Remove the ‘,’ at the end

    The resulting data should like like this:

    {
        "Name": "PI2018",
        "Prefix": "CS",
        "TagFilter": "",
        "Provider": "PIOLEDB",
        "DataSource": "cs-pi2018.trendminer.net",
        "UserId": "pi2018user",
        "Password": "mypassword",
        "Version": "other",
        "OnlySupportRawValues": false,
        "Properties": [
            {
                "key": "TAGFILTER",
                "value": """
            }
        ]
    }

Important

Never change the “Prefix” or the “Name” when moving a data source. This will result in broken views and formulas.

  • Add the data source to connector B doing a POST /database passing on the edited data source details as the body of the POST call.

  • Conditional step: this step only needs to be executed in case you are changing the connector for an ODBC/OleDB or SQLite data source.

    • Copy over all ODBC/OleDB/SQLite configuration files from connector A to connector B. When copying please make sure the same folder structure is maintained.

      ODBC_data_source_4.png
  • Sync connector A

  • Sync connector B

  • Run a global monitor health check

Note

Running a monitor health check is recommended as moving data sources might have temporarily made them unavailable, resulting in system-disabled monitors.